Take control of solvents!
- Vapor and Fire Protection Built-in pressure relief relieves pressure in extreme temperatures. Minimize vapor release or safely exhaust them back into a fume hood. "Quick-Disconnect" valve further prevents vapor release or solvent leakage.
- Safeguard against Accidents Avoid "knock over" spills and broken glass that is common with bottle collection devices. Reduce leaks when disconnecting for disposal.
- Maximize Safety and Convenience
Tighter control during the collection and disposal process maintains safety.
Quick-Disconnect Safety Disposal Cans offer a safe and easy way to collect liquid waste. Quick-disconnect fittings allow free flow of solvent into container through tubing. Durable polyethylene container with large, strategically placed opening facilitates controlled pouring into larger vessels for proper hazardous waste disposal. Opening is equipped with a stainless steel flame arrester which dissipates heat to prevent flashback ignition. Fixed position latch on handle allows lid to stay open for easier pouring. Translucent color lets you check liquid level at a glance.
Hands-free liquid waste accumulation is ideal for HPLC applications and is suitable for either pump fed or gravity flow HPLC waste methods. Double fittings eliminate back pressure in liquid flow disposal line and provide controlled handling of vapors. Container automatically vents between 3 and 5 psig.
Exclusive "quick-disconnect" mechanism offers a convenient means of detaching can from the HPLC process without having to disengage tubing already connected to the machine. Both coupling and disconnect are valved to prevent vapor release or solvent leakage.
Models with stainless steel fittings offer Polytetrafluoroethylene (PTFE) o-rings while more economically priced polypropylene fittings offer EPDM o-rings. Choose the one which is compatible with the solvent discharged from your HPLC unit.
Meets OSHA 29 CFR 1910.106(a)(29): Safety can shall mean an approved container, of not more than 5 gallons capacity, having a spring-closing lid and spout cover and so designed that it will safely relieve internal pressure when subjected to fire exposure.
| Centura
Prefabricated Quick-Disconnect Safety Disposal Cans |
| Model # |
Capacity |
Outer Dia. x H |
HPLC Material |
O-ring |
Tubing Size |
Wt (Lbs/Kg) |
| JP-12752TF |
2 gallon |
12" x 14.75" |
Stainless Steel |
Teflon |
.375" |
7/3 |
| JP-12752PP |
2 gallon |
12" x 14.75" |
Polypropylene |
EPDM |
.375" |
7/3 |
| JP-12755TF |
5 gallon |
12" x 20" |
Stainless Steel |
Teflon |
.375" |
10/5 |
| JP-12755PP |
5 gallon |
12" x 20" |
Polypropylene |
EPDM |
.375" |
10/5 |
Centura® Coalescing Carbon Filters minimize odor by capturing 99% of liquid particulates released in the form of gaseous vapor. The two-stage vent filter is easy to install, snapping conveniently into the factory installed "Quick Disconnect" fitting. A convenient color-changing Carbon Cartridge (top portion) changes from deep purple to black as hydrocarbons are absorbed to indicate when replacement is necessary. The Coalescing Filter (bottom portion) can be reused with new carbon filters several times and can be replaced after 3-4 carbon filter cycles. Filters have been designed for use with all round TF, PP and Custom Built "Quick Disconnect" 2 and 5-gallon cans.
Two-stage filter addresses environmental concerns by capturing 99% of liquid particulates to minimize odor. Filter comes fully assembled and quickly snaps into fitting on can for easy set-up. Top carbon filter with filter replacement window simply twists on to coalescing filter for easy filter changes.
When used with Justrite Quick Disconnect HPLC Safety Disposal Cans, the Polyethylene Manifold Kit is the most cost-effective way to safely collect waste. The HPLC Poly Manifold enables up to six waste lines (per manifold) from HPLC processes to be fed into a single intake fitting. Manifolds have six 1/4-28 ports and one 3/8" NPT port (all come with caps for unused ports) and either one quick disconnect in No. 316 stainless steel or polypropylene, or a No. 316 stainless steel stacker connector. The six ports are tapped to accommodate the 1/4-28 threads of the separately available compression fittings.
The compression fittings, sold in sets of six, accommodate tubing sizes of either 1/16" and 1/8" OD. The fittings are approximately 1" long and made of Tefzel®. They include ferrules for a compression fit to the waste line.
Manifold #28179 has a "stacker" connection enabling it to attach on top of a #28177 or 28178 and allowing up to a total of 12 waste lines to be fed into the disposal can. Multiple manifolds may be used on a custom-designed Quick Disconnect container as long as one disconnect remains unused to permit venting and prevent back pressure. Safety Can with Manifold installed is OSHA complaint and meets NFPA Code 30.
Please Note: Justrite’s poly manifold is available as a lower cost alternative to stainless steel for those customers who can use poly due to the chemicals that will flow through it. This is also why Justrite has offered poly and stainless quick disconnects for its HPLC Waste Cans. There are an endless number of potential chemicals, waste chemicals, chemical combinations, and heated chemicals that could pass through the poly manifold. Some of these may react with the manifold’s Delrin* acetal resin material. The user needs to make the final determination as to whether a poly or stainless steel manifold would work best for their application. More information on Delrin* acetal material, including chemical compatibility (Table 11 on page 42), can be found at: http://plastics.dupont.com/plastics/pdflit/americas/delrin/230323c.pdf
*Delrin is a registered trademark of DuPont. The generic terms for Delrin include acetal resin, polyoxymethylene, and polyacetal.
The convenient, cost-effective way to safely collect waste from multiple HPLC machines
The HPLC Manifold Kit, designed for use with Justrite FM Approved Quick Disconnect Safety Cans, enables up to four waste lines from HPLC processes to be fed into a single intake fitting. Kit includes enough fittings to accommodate tube lines either 1/16" (1.6 mm) OD or 1/8" (3.2 mm) OD. Approximately 31/2" (89 mm) long and made of 316 stainless steel, it comes with a pre-installed stainless steel disconnect plug that fits into the stainless steel fitting on any TF or BY series or custom made Quick-Disconnect Can. Four ports are tapped to accommodate 1/4-28 threads of the supplied fittings. Peek fittings include four each: 1/16" (1.6 mm) and 1/8" (3.2 mm) OD tube fittings with corresponding PCTFE ferrules for compression fit of waste line. Four plug caps are provided to close unused ports and reduce vapor release. Multiple Manifolds may be used on a custom-designed Quick Disconnect container as long as one fitting remains unused to permit venting and prevent back pressure. Safety Can with Manifold installed is OSHA complaint and meets NFPA Code 30.
| Model # |
Heavy Duty Stainless Steel HPLC Accessories for Quick-Disconnect Safety Cans |
| JP-28168 |
HPLC
Manifold Kit w/ Stainless Steel Fitting for JP-12752TF or JP-12755TF |
| JP-28174 |
Replacement 1/16" OD tube fittings with PCTFE ferrules for SS, set of 4 |
| JP-28175 |
Replacement 1/8" OD tube fittings with PCTFE ferrules for SS, set of 4 |
| JP-28176 |
Replacement Plug Caps for SS fittings on Justrite QD Can HPLC Manifold Kit, set of 4 |