Logo Slogan
Cart Log In / Register | My Cart (Your cart is empty.)  
Categories
-Anti Fatigue Mats
-Bags & Liners
-Bollard Posts
-Bottles and Containers
-Carts, Caddies & Jacks
-Chromatography
-Cleaning Tanks
-Cigarette Disposal
-Drums
-Drum Funnels
-ECO Funnels
-Other Funnels
-Emergency Care
-General Lab Supplies
-Guards and Protectors
-Outdoor Storage
-Parking Lot and Traffic Accessories
-Protective Clothing
-Ramps and Dock Plates
-Recycle Gas/ Aerosol
-Recycling Bins
-Safety Cabinets
-Safety Cans
-Spill Control
-Vacuum Filter Funnels
-Waste Containers
Expand/Collapse
  Subscribe to CP Lab Safety NewslettersGet LinkedIn with CP Lab SafetyFollow CP Lab Safety on Twitter!Follow CP Lab Safety on FaceBook!
Manufacturers
SSL Certified. 128-bit secure transactions

Online Payments

Safety Cabinets: Flammable Cabinets and Acid Cabinets

Safety Cabinets Ship Free in US!*

flammable safety cabinetacid cabinetcombustible safety cabinetpesticide drum safety cabinethigh security safety cabinetwhite drum cabinetssafety cabinet storage chestsafety cabinet accessories

Safety Cabinet RegulationsSafety Cabinet Regulations and Requirements

*We offer FREE SHIPPING on Safety Cabinets shipped within the contiguous ("lower 48") United States. For an international, HI or AK shipping quote, please call us at 1-415-883-2600 or email us.

 

CP Lab Safety distributes Justrite and Eagle safety cabinets for the safe storage of flammable liquids, acids, paints, inks, and pesticides. OSHA and EPA regulations require that hazardous materials are properly stored inside fire proof safety cabinets. The safety cabinets available on this page will help you safely manage a variety of flammable, toxic and combustible chemicals.

Safety Cabinets Safely Store Flammable and Combustible Liquids

To prevent fires, hazardous liquids need special precautions taken for their storage, handling and use. The National Fire Protection Agency (NFPA) and the International Code Council (ICC) have developed guidelines for the safe storage and use of flammable and combustible liquids under the Uniform Fire Code. These guidelines are not mandatory unless a federal, state or local authority chooses to use them.

Mandatory regulations have been developed, however, by Occupational Safety and Health Administration (OSHA). They have specified safe handling practices General Industry (29 CFR 1910.106).

Defining Flammable and Combustible Liquids

To understand OSHA requirements for the safe storage of flammable and combustible liquids, we must begin by defining the two. The flash point and boiling point determine the class of a liquid.

A flammable liquid is any liquid having a flash point below 100° F (37.8°C) (except any mixture having components with flash points of 100°F (37.8°C) or higher, the total of which make up 99 percent or more of the mixture)(1910.106(a)(19)). Flammable liquids are categorized into three groups, as follows:

Class IA Flammable Liquid
Liquids having flash points below 73°F (22.8°C) and having boiling points below 100°F (37.8°C) (1910.106(a)(19)(i)). Examples: Acetaldehyde, ethyl ether and cyclohexane.

Class IB Flammable Liquid
Liquids having flash points below 73°F (22.8°C) and having boiling points at or above 100° F (37.8°C) (1910.106(a)(19)(ii)). Examples: Acetone, benzene and toluene.

Class IC Flammable Liquid
Liquids having flash points at or above 73°F (22.8°C) and below 100° F (37.8°C) (1910.106(a)(19)(iii)). Examples: Hydrazine, styrene and turpentine.


A combustible liquid is any liquid having a flash point at or above 100°F (37.8°C) (1910.106(a)(18)). Combustible liquids are divided into two classes:

Class II Combustible Liquid
Liquids having flash points at or above 100°F (37.8°C) and below 140°F (60°C), except any mixture having components with flash points of 200°F (93.3°C) or higher, the volume of which make up 99 percent or more of the total volume of the mixture (1910.106(a)(18)(i)). Examples: Acetic acid, naphtha and stoddard solvent.

Class III Combustible Liquid
Liquids having flash points at or above 140°F (60°C) (1910.106(a)(18)(ii)). Class III liquids are subdivided into two subclasses:

Class IIIA Combustible Liquid
Liquids having flash points at or above 140°F (60°C) and below 200°F, except any mixture having components with flash points of 200°F (93.3°C) or higher, the total volume of which make up 99 percent or more of the total volume of the mixture (1910.106(a)(18)(ii)(a)). Examples: Cyclohexanol, formic acid and nitrobenzene.

Class IIIB Combustible Liquid
Liquids having flash points at or above 200°F (93.3°C) (1910.106(a)(18)(ii)(b)). Examples: Formalin and picric acid. Per 1910.106(a)(18)(ii)(b) "Class IIIB liquids" shall include those with flash points at or above 200°F (93.3°C). This section does not cover Class IIIB liquids. Where the term "Class III liquids" is used in the section, it shall mean only Class IIIA liquids. (Class IIIB is used in this document for reference purposes only.)

*Note: When a combustible liquid is heated for use to within 30°F (16.7°C) of its flash point, it shall be handled in accordance with the requirements for the next lower class of liquids (1910.106(a)(18)(iii)).

Whether a liquid is a Class IB Flammable Liquid or Class IIIA Combustible Liquid is not the only factor you should consider when determining your safe storage needs. You also need to consider ignition temperature, explosive limits (LEL or UEL), vapor pressure, specific gravity and vapor density if you want to design a truly safe storage system.


Flammable and Combustible Liquids Safety Cans

One technique to reduce the hazards associated with flammable and combustible liquids is the use of safety cans. OSHA defines a safety can as:

"An approved container, of not more than 5 gallons capacity, having a spring-closing lid and spout cover and so designed that it will safely relieve internal pressure when subjected to fire exposure" (1910.106(a)(29))."

This definition allows a wide variety of containers to be considered safety cans. However, many local laws and insurance carriers require safety cans to be Factory Mutual (FM) or Underwriter Laboratory (UL) approved. These two organizations are nationally recognized independent testing laboratories to which manufacturers submit products for evaluation of their ability to meet safety requirements under intended use. Products that meet the requirements are given either a UL product or FM approved. Both laboratories are also recognized by OSHA.

In addition, 29 CFR 1910.106 limits the amount of liquid in a single safety can. The following chart shows the allowable amounts for each class of liquid.

MAXIMUM ALLOWABLE SIZE OF CONTAINERS AND METAL PORTABLE TANKS
Container Type Flammable Liquids Combustible Liquids
Class IA Class IB Class IC Class II Class III
Glass or approved plastic 1 pint 1 quart 1 gallon 1 gallon 1 gallon
Metal (other than DOT drums) 1 gallon 5 gallon 5 gallon 5 gallon 5 gallon
Safety Cans 2 gallon 5 gallon 5 gallon 5 gallon 5 gallon
Metal Drum (DOT spec.) 60 gallon 60 gallon 60 gallon 60 gallon 60 gallon
Approved Metal Portable Tanks 660 gallon 660 gallon 660 gallon 660 gallon 660 gallon
 

Exceptions to this rule: Medicines, beverages, foodstuffs, cosmetics and other common consumer products, when packaged according to commonly accepted practice

29 CFR 1910.106 also limits the total amount of a liquid kept outside of a safety cabinet or storage room. The quantity of liquid that may be stored outside of an inside storage room or flammable liquid storage cabinets in any one fire area of a building cannot exceed:

  • 25 gallons of Class IA liquids in containers
  • 120 gallons of Class IB, IC, II or III liquids in containers
  • 660 gallons of Class IB, IC, II or III liquids in a single portable tank

The amount of liquid storage and location of cabinets is regulated. 1910.106 (d)(3) states, "Not more than 60 gallons of Class I or Class II liquids, nor more than 120 gallons of Class III liquids may be stored in a storage cabinet." Also, according to NFPA 304.3.2, not more than three (3) such cabinets may be located in a single fire area.

Safety Storage Cabinets

Another fundamental means of fire protection is the use of flammable storage safety cabinets. The NFPA, OSHA and UFC require flammable cabinets to be designed and constructed to specific requirements. 1910.106(d)(3)(ii)(a) states that metal cabinet shall be constructed in the following manner:

  • Bottom, top and sides of cabinet shall be at least No. 18 ga. sheet steel
  • Cabinet must be doubled walled with 1½" airspace
  • Joints shall be riveted, welded or made tight by some equally effective means
  • Door shall have a three-point latch
  • Door sill shall be raised at least 2" above the cabinet bottom to retain spilled liquid within the cabinet
  • Cabinet shall have a "FLAMMABLE—KEEP FIRE AWAY" legend

These regulations also provide an option for wood cabinets. 1910.106(d)(3)(ii)(b) states that wood cabinets shall be constructed in the following manner:

  • Bottom, top and sides of cabinet shall be at constructed of exterior grade plywood at least 1" thick
  • Plywood shall not break down or delaminate under fire conditions
  • Joints shall be rebutted and fastened in two directions with flathead wood screws
  • When more than one door is used, they should have a rebutted overlap of not less than 1"
  • Doors shall be equipped with latches and hinges that are mounted to not lose their holding capacity when subjected to fire
  • Door sill or pan shall be raised at least 2" above the cabinet bottom to retain spilled liquid within the cabinet
  • Cabinet must have a "FLAMMABLE—KEEP FIRE AWAY" legend

In addition to the requirements listed above, the UFC (Uniform Fire Code) also requires self-closing doors. Most local authorities use one or more of these standards as a foundation for establishing local codes.

Fire Areas

OSHA does not provide a definition of a fire area in their standard. However, a fire area is defined by NFPA Code 30 (1.6.15) as, "An area of a building separated from the remainder of the building by construction having a fire resistance of at least 1 hour and having all communicating openings properly protected by an assembly having a fire resistance rating of at least 1 hour."

The NFPA also provides a special provision for the grouping of flammable cabinets in an industrial facility. Because most industrial settings do not have walls or barriers within a facility, "In an industrial occupancy, additional cabinets may be located in the same fire area if the additional cabinets, or the group of not more than three (3) cabinets, is separated from the other cabinets or group of cabinets by at least 100 feet (30 m)." (4.3.2 Exception 1)

Flammable Combustible Liquids Questions

Frequently Asked Questions

Q. When dispensing flammable liquids, do I have to use bonding and grounding wires?

A. According to 1910.106(e)(6)(ii), only Class I liquids are required to be bonded and grounded. However, for your own safety, bonding and grounding should always be used when dispensing flammable or combustible liquids.

Q. Am I required to have a flammable storage cabinet?

A. OSHA does not require the use of flammable storage cabinets unless the total amount of flammable and/or combustible liquids reaches a given amount. Local authorities and insurance companies may require the use of flammable storage cabinets in quantities less than that of OSHA.

Q. What is the difference between type I and type II safety cans?

A. A Type I safety can has one spout for both pouring and filling. A Type II safety can has two openings; one for pouring and one for filling. See LSS Tech Clip 1 for more information.

Q. What is a flame arrestor, and what purpose does it serve?

A. A flame arrestor is a mesh or perforated metal insert within a flammable storage container (safety can, cabinet) which protects its contents from external flames or ignition. It also dissipates heat. All Type I, Type II, disposal and specialty cans include a flame arrestor.

Q. Are flammable cabinets required to have mechanical ventilation?

A. OSHA does not normally require the use of mechanical ventilation. The NFPA recommends that cabinets not be mechanically ventilated, but if they are, they should be ventilated in accordance to NFPA 91 Exhaust Systems for Air Conveying of Materials.

Sources for More Information:

National Institute of Occupational Safety & Health, U.S. Department of Health and Human Services. (Washington: GPO 2005).

National Fire Protection Association, Flammable and Combustible Liquids Code Handbook, Sixth edition, ed. Robert Benedetti, 1996.

United States Office of the Federal Register National Archives and Records Administration, 29 Code of Federal Regulations Parts 1900 to 1910, (Washington: GPO 1994).

Resources:

Article Source: http://www.labsafety.com/refinfo/ezfacts/ezf179.htm

Search
My Cart
Your cart is empty.

Need Help? Call us!
1 (888) 322-5722 - toll free
1 (415) 883-2600 - local
Request a Quote

What's New?
Now Showing - CP Lab Safety Video

“...Thanks for the excellent customer service I received from you and your company. It is so very nice to work with a company who stands behind their products as CP Lab Safety does. Thank you for being first class. I will definitely keep recommending your products."
-- Tim Wisner, Sr. Safety Officer, UNC Health Care

"The ECO Funnel™ has helped us meet environmental regulation requirements [and] at the same time provides added protection and spill prevention for our handling operations."
-- Don Pearson, Roche Diagnostics

"We handle highly toxic chemicals and are constantly looking for ways to improve the handling and safe disposal of these chemicals. The ECO Funnel™ has been great in helping me meet these challenges."
-- Nancy Davis, QC Manager, Amvac Chemical Corp

"The Safety ECO Funnel™ is an ideal containment system that eliminates the danger of ignited vapors and spills from open chemical waste containers."
-- Steve Carroll, Fire Marshall and Biotech Inspector, San Diego

"You make the whole process so easy for me. [My] colleagues really like them!! Safe and clean.”
--Tom Vu, Biofuels Safety/ OE Coordinator, Chevron

Signup for our newsletter
Enter E‑mail:
Unsubscribe »
Home Product Directory FAQ About Us Privacy Policy Testimonials Ordering Contact Us Partners
© 1996 - 2010 CP Lab Safety Powered by ClearCart Shopping Cart Software.