Untitled Document

These Safety Can Compatibility Guides for Justrite and Eagle Galvanized Steel, Stainless Steel and Polyethylene Safety Cans are for reference only. They is not a substitute for the user clearly understanding the nature and proper use of the chemicals being used, area hygiene and environmental conditions, and the laws governing use. Check with the chemical manufacturer for more information. Mixing of different chemicals and chemical concentrations may impact suitability and compatibility. This chart is not a guarantee, express or implied, of fitness of use and CP Lab Safety, Justrite and Eagle assume no responsibility for the use or misuse of this information.

Justrite Safety Can Compatibility Guide:

Justrite Safety Can Compatibility Guide

Eagle Safety Can Compatibility Guide:

SOLVENT
Galvanized Steel/ Terne Plate
Polyethylene
Stainless Steel
Acetic Acid
N
Y
Y
Acetone
Y*
Y
Y
Aniline
N
Y
Y
Benzene
N
Y
Y
Butadiene
N
N
Y
2-Butanone
Y*
Y
Y
Butylene
Y
N
Y
Chlorofluorocarbons
N
N
Y
Cyclohexane
Y
N
N
Cyclohexanone
N
N
Y
Ethanol
N
Y
Y
Ethyl Acetate
N
Y
Y
Ethyl Ether
Y*
N
Y
Ethylene Glycol
N
Y
Y
Fuel Oil
Y
Y
Y
Gasoline
Y
Y
Y
Heptane
Y
Y
Y
Hexane
Y
N
Y
Kerosene
Y
Y
Y
Methanol
N
Y
Y
Methylene Chloride
N
N
Y
Methyl Ethyl Ketone
Y*
N
Y
Methyl Isobutyl Ketone
Y*
Y
Y
Pentane
Y
Y
N
Petroleum Ether
Y
N
Y
Toluene
Y
Y
Y
Trichloroethylene
N
N
Y
Xylene
Y
Y
Y

Y = Yes   N = No

  • Galvanized Steel/Terne Plate: when chemical purity is not critical. Some chemicals may adversely affect paint.
  • Polyethylene for storing acids, caustics and other corrosive chemicals.
  • Stainless Steel: when chemical purity is critical.

* May discolor solvent if water present.

CAUTION: Resistance to mixed solvents is unpredictable. This Guide DOES NOT apply to mixtures, even if the can is compatible with all components of the mixture.

© Lab Safety Supply, Inc., Janesville, WI
Search
My Cart
Your cart is empty.

Need Help? Call us!
1 (888) 322-5722 - toll free
1 (415) 883-2600 - local
Request a Quote

What's New?
Now Showing - CP Lab Safety Video

"The ECO Funnel™ has helped us meet environmental regulation requirements [and] at the same time provides added protection and spill prevention for our handling operations."
-- Don Pearson, Roche Diagnostics

"We handle highly toxic chemicals and are constantly looking for ways to improve the handling and safe disposal of these chemicals. The ECO Funnel™ has been great in helping me meet these challenges."
-- Nancy Davis, QC Manager, Amvac Chemical Corp

"The Safety ECO Funnel™ is an ideal containment system that eliminates the danger of ignited vapors and spills from open chemical waste containers."
-- Steve Carroll, Fire Marshall and Biotech Inspector, San Diego

"You make the whole process so easy for me. [My] colleagues really like them!! Safe and clean.”
--Tom Vu, Biofuels Safety/ OE Coordinator, Chevron

Signup for our newsletter
Enter E‑mail:
Unsubscribe »
Home Product Directory FAQ About Us Privacy Policy Testimonials Ordering Contact Us Partners
© 1996 - 2010 CP Lab Safety Powered by ClearCart Shopping Cart Software.