Accuris
QuickSilver Tris-Glycine-SDS Protein Electrophoresis Instant Buffer Mix, pack/50
- Part Number:
- BM-EB1100
- Lead Time:
- 5-7 days
- Minimum Purchase:
- 1 unit
- Shipping:
- FREE SHIPPING on most orders over $50*
- Quantity:
- 100
- Style:
- chemical
Description
QuickSilver Tris-Glycine-SDS Protein Electrophoresis Instant Buffer Mix. Accuris QuickSilver™ Powdered Instant Buffer Packs each provide a liter of fresh buffer. The buffer pouches are supplied in a convenient dispenser box and should be stored at room temperature in a clean, dry location. Protect from moisture. For research purposes only. Not intended for therapeutic or diagnostic use.
Protein Electrophoresis Buffers
QuickSilver™ TGS (Tris-Glycine-SDS)
Tris-Glycine-SDS is one of the most common running buffers used for SDS-PAGE. A 1X solution contains 25mM Tris, 192mM Glycine and 0.1% SDS.
?Buffer | Cat # | 1X solution in water | pH Range | Max dissolve | Tris-Glycine-SDS | BM-EB1100 | 25mM Tris, 192mM Glycine, 0.1% SDS | 8.1-8.5 | 200 seconds |
- Premeasured pouches make 1 liter of 1x buffer solution
- Just empty pouch into water and stir - no diluting of stock solutions
- No pH adjustment necessary
- Quality and consistency guaranteed
- Nuclease and protease free
- Long shelf life
- QuickSilver Instruction Insert
- QuickSilver Brochure
Item No. | Description |
---|---|
BM-EB1000 | QuickSilver TAE Buffer Powder, 100 pouches |
BM-EB1001 | QuickSilver TBE Buffer Powder, 50 pouches |
BM-EB1002 | QuickSilver Fast Running Buffer Powder, 100 pouches |
BM-EB1100 | QuickSilver Tris-Glycine-SDS Buffer Powder, 50 pouches |
BM-EB1101 | QuickSilver Tris-MES-SDS Buffer Powder, 50 pouches |
BM-EB1102 | QuickSilver Tris-MOPS-SDS Buffer Powder, 50 pouches |
BM-EB1200 | QuickSilver PBS Buffer Powder, 100 pouches |
BM-EB1201 | QuickSilver PBS-T Buffer Powder, 100 pouches |
BM-EB1202 | QuickSilver TBS Buffer Powder, 100 pouches |
BM-EB1203 | QuickSilver TBS-T Buffer Powder, 100 pouches |
Instructions for making 1 liter of 1X solution:
- Add contents of buffer pouch to a graduated cylinder or beaker.
- Slowly add distilled water to 1 liter.
- Mix well until all granules are dissolved (a magnetic stirrer can be used for faser results).
- Add additional water to bring the volume to 1L, if necessary.
Note: cell culture and chromatography applications may require a high purity buffer. For these applications, it is recommended to use ultra-pure water and filter the buffer through a 0.22µM filter after dissolved. Also be sure to use a clean, sterile container. Included labels can be placed on bottles. Read and follow handling instructions on the SDS (available at www.accuris-usa.com). Wear proper protective eyewear, clothing and glasses. Clean up any spills immediately.
Quality Control
QuickSilver Buffers are tested for pH, solubility and the absence of nuclease and protease activity. This product is manufactured under a comprehensive quality management system, following ISO 9001:2008 standards.
Please note: This product is not returnable.