Description
Micro-Scientific Micro-Cide28 HLD™ Disinfectant, 1 Gallon. A 28-day, reusable, high-level disinfectant. It can be used as a standard soak or in automatic reprocessing units. (This item ships within the continental US Only). Micro-Cide 28 HLD is a 3% glutaraldehyde solution with attached powder activator. Once activated, Micro-Cide 28 HLD can be used for 28 days to provide high level disinfection or sterilization, providing the solution is above the 1.8% minimum effective concentration and is used according to directions for use.
- Provides a way to effectively sterilize or achieve high level disinfection of heat sensitive reusable medical devices.
- Achieves high level disinfection of instruments in 25 minutes providing
directions for use are followed. - Sterilizes instruments in 10 hours providing directions for use are followed.
CHEMISTRY:
Micro-Cide 28 HLD is a virtually surfactant-free, free rinsing activated glutaraldehyde liquid chemical sterilant and high-level disinfectant. Its active ingredient is glutaraldehyde in a nominal concentration of 3%. When the powdered activator is added, the solution turns green in color to indicate its readiness for use. In addition to the active ingredient, this ready-to-use solution contains buffers, wetting agents, a rust and corrosion inhibitor and a pleasant fragrance.
MICROBIOLOGY:
Micro-Cide 28 HLD produces high-level disinfection at room temperature in as little time as 25 minutes and complete sterilization in 10 hours at room temperature.
Representative microorganisms tested include:
Bacterial Spores
- Bacillus subtillus
- Clostridium sporogenes
Vegetative Bacteria
- Staphylococcus aureus
- Salmonella cholerasuis
- Pseudomonas aeruginosa
Mycobacteria
- Mycobacterium tuberculosis (var: BCG bovis)
- Mycobacterium tuberculosis (smegmatis)
Viruses
- Herpes simplex virus Type I
- Poliovirus Type I
- HIV-1 (Associated with AIDS)
Fungi
- Trichophyton mentagrophytes
- Aspergillis Niger
CLINICAL / IN-USE STUDIES:
Reprocessing flexible fiber endoscopes in-use studies supports the effectiveness of Micro-Cide 28 HLD in actual use. (ASTM 1518-94 protocol). In addition, a simulated use-test was conducted to support the contact condition for high-level disinfection of endoscopes at 25°C at 25 minutes. The results demonstrate the effectiveness of Micro-Cide 28 HLD to kill M.Terrae dried on flexible fiber endoscopes.
(Studies were performed after 28 days of simulated re-use following prescribed AOAC testing methods).
What test strips do you recommend to ensure the MEC is at necessary level for reuse?
Micro-Cide™ 28 HLD 3% Glutaraldehyde may be reused for a maximum of 28 days provided the minimum effective concentration of 1.8% Glutaraldehyde, time and temperature are maintained. Micro-MEC™ 1.8% Glutaraldehyde Monitor Strip* should be used before each use of Micro-Cide™ 28 HLD 3% Glutaraldehyde solution to determine the glutaraldehyde concentration is above the minimum effective concentration of 1.8%.
Do not use beyond 28 days even if the concentration of Glutaraldehyde is above the minimum effective concentration (1.8%) as indicated by the Micro-MEC™ 1.8% Glutaraldehyde Monitor Strip*. See the Package Insert for additional instructions and information regarding the reuse of Micro-Cide™ 28 HLD 3% Glutaraldehyde.
*Micro-MEC™ is a trademark of Micro-Scientific, LLC. The Micro-MEC™ 1.8% Glutaraldehyde Monitor Strip has been verified for use with Micro-Cide™ 28 HLD 3% Glutaraldehyde solution and provides a &'margin of safety'; above the Minimum Effective Concentration of 1.8%.
WARNING: This product can expose you to b-Myrcene, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.
Please note: this item ships within the US Only.